Home - What's New - Product Details - Applications - Contact Us

PCM Energy P. Ltd

Natural Cooling by Phase Change Materials
Customized PCMs

We have several Associated Units
ISO-9001 Certificate
"REACH" Pre-registered

For Translating this page in your language use this translation tool.

PCM Phase Change Material Manufacturer for Air Condition AC & Heating HVAC USA

AC Heat Exchanger Profile
Heat Exchanger Stackable & Wall Mountable PCM-Filled Profiles
PCM AC Phase Change Material Air Conditioned
Natural Air conditioning with PCM in Ceiling PCM Cooled AC Office building in Netherlands.

Natural Cool housePl click to Enlarge

Please check Phase Change Material Airconditioner and Houston Phase Change Material Air Conditioner to correlate the temperature profiles.

Dallas Average Temperature:

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 54°F - 34°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 60°F - 39°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 68°F - 46°F - 22 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 76°F - 54°F - 22 - Balance @ 65°F- - Heats with PCM 77 (or 80+77)
May-- - 83°F - 63°F - 20 - Balance @ 73°F- - Cools & Heats with PCM 77 (or 80+77)
Jun-- - 91°F - 70°F - 21 - Balance @ 80°F- - Cools with PCM 77 (or 80+77)
Jul-- - 95°F - 75°F - 20 - Balance @ 85°F- - Cools with PCM 77 (or 80+77)
Aug-- - 95°F - 74°F - 21 - Balance @ 84°F- - Cools with PCM 77 (or 80+77)
Sept- - 88°F - 67°F - 21 - Balance @ 77°F- - Cools with PCM 77 (or 80+77)
Oct-- - 78°F - 56°F - 22 - Balance @ 67°F- - Heats with PCM 77 (or 80+77)
Nov-- - 65°F - 45°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 57°F - 37°F - 20 - Can not balance - Use heater during non-peak electric tariff hours

Austin Average Temperature:

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 60°F - 40°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 65°F - 44°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 72°F - 51°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 79°F - 58°F - 21 - Balance @ 69°F- - Heats with PCM 77 (or 80+77)
May-- - 85°F - 65°F - 20 - Balance @ 75°F- - Cools & Heats with PCM 77 (or 80+77)
Jun-- - 91°F - 71°F - 20 - Balance @ 81°F- - Cools with PCM 77 (or 80+77)
Jul-- - 95°F - 73°F - 22 - Balance @ 84°F- - Cools with PCM 77 (or 80+77)
Aug-- - 96°F - 73°F - 23 - Balance @ 84°F- - Cools with PCM 77 (or 80+77)
Sept- - 90°F - 69°F - 21 - Balance @ 80°F- - Cools with PCM 77 (or 80+77)
Oct-- - 81°F - 59°F - 22 - Balance @ 70°F- - Heats with PCM 77 (or 80+77)
Nov-- - 70°F - 49°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 62°F - 42°F - 20 - Can not balance - Use heater during non-peak electric tariff hours

Atlanta - Georgia Average Temperature:

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 52°F - 33°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 57°F - 36°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 65°F - 43°F - 22 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 73°F - 50°F - 23 - Can not balance - Use heater during non-peak electric tariff hours
May-- - 80°F - 59°F - 21 - Balance @ 70°F- - Cools & Heats with PCM 75 (or 80+75)
Jun-- - 87°F - 67°F - 20 - Balance @ 77°F- - Cools with PCM 75 (or 80+75)
Jul-- - 89°F - 70°F - 19 - Balance @ 80°F- - Cools with PCM 75 (or 80+75)
Aug-- - 88°F - 70°F - 18 - Balance @ 79°F- - Cools with PCM 75 (or 80+75)
Sept- - 82°F - 64°F - 18 - Balance @ 73°F- - Cools with PCM 75 (or 80+75)
Oct-- - 73°F - 53°F - 20 - Balance @ 63°F- - Use heater during non-peak electric tariff hours
Nov-- - 63°F - 43°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 55°F - 36°F - 19 - Can not balance - Use heater during non-peak electric tariff hours

Richmond - Virginia Average Temperature: (Washington DC Surrounding)

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 45°F - 28°F - 17 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 49°F - 30°F - 19 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 58°F - 37°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 68°F - 45°F - 23 - Can not balance - Use heater during non-peak electric tariff hours
May-- - 76°F - 55°F - 21 - Balance @ 65°F- - Cools & Heats with PCM 70 (or 75+70)
Jun-- - 83°F - 63°F - 20 - Balance @ 73°F- - Cools with PCM 70 (or 75+70)
Jul-- - 87°F - 68°F - 19 - Balance @ 77°F- - Cools with PCM 70 (or 75+70)
Aug-- - 85°F - 67°F - 18 - Balance @ 76°F- - Cools with PCM 70 (or 75+70)
Sept- - 79°F - 60°F - 19 - Balance @ 70°F- - Cools & Heats with PCM 70 (or 75+70)
Oct-- - 69°F - 47°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Nov-- - 59°F - 38°F - 21 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 49°F - 31°F - 18 - Can not balance - Use heater during non-peak electric tariff hours

Chicago Illinois Average Temperature:

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 30°F - 14°F - 16 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 35°F - 19°F - 16 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 46°F - 28°F - 18 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 58°F - 38°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
May-- - 70°F - 47°F - 23 - Balance @ 65°F- - Cools & Heats with PCM 70 (or 75+70)
Jun-- - 79°F - 57°F - 22 - Balance @ 73°F- - Cools & Heats with PCM 70 (or 75+70)
Jul-- - 84°F - 63°F - 21 - Balance @ 77°F- - Cools & Heats with PCM 70 (or 75+70)
Aug-- - 81°F - 62°F - 19 - Balance @ 76°F- - Cools & Heats with PCM 70 (or 75+70)
Sept- - 74°F - 54°F - 20 - Balance @ 70°F- - Cools & Heats with PCM 70 (or 75+70)
Oct-- - 62°F - 42°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Nov-- - 47°F - 32°F - 15 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 34°F - 20°F - 14 - Can not balance - Use heater during non-peak electric tariff hours

Las Vegas Average Temperature:

Month - High - Low- - ΔT - Mid-way-------- - Comments
Jan-- - 57°F - 37°F - 20 - Can not balance - Use heater during non-peak electric tariff hours
Feb-- - 63°F - 41°F - 22 - Can not balance - Use heater during non-peak electric tariff hours
Mar-- - 69°F - 47°F - 22 - Can not balance - Use heater during non-peak electric tariff hours
Apr-- - 78°F - 53°F - 25 - Balance @ 65°F- - Cools & Heats with PCM 77 (or 77+82)
May-- - 88°F - 62°F - 26 - Balance @ 75°F- - Cools & Heats with PCM 77 (or 77+82)
Jun-- - 99°F - 72°F - 27 - Balance @ 86°F- - Cools with PCM 77 (or 77+82)
Jul-- -104°F - 78°F - 26 - Balance @ 90°F- - Cools with PCM 77 (or 77+82)
Aug-- -102°F - 77°F - 25 - Balance @ 89°F- - Cools with PCM 77 (or 77+82)
Sept- - 94°F - 69°F - 25 - Balance @ 81°F- - Cools & Heats with PCM 77
Oct-- - 81°F - 56°F - 25 - Balance @ 69°F- - Cools & Heats with PCM 77
Nov-- - 66°F - 44°F - 22 - Can not balance - Use heater during non-peak electric tariff hours
Dec-- - 57°F - 36°F - 21 - Can not balance - Use heater during non-peak electric tariff hours

AC Heat Exchanger Profile
Heat Exchanger Stackable & Wall Mountable PCM-Filled Profiles

PCM Phase Change Material Suppliers & Exporters to USA (Representatives in Houston Texas & Chicago Illinois) Canada UAE Dubai & Europe South Africa Egypt Turkey Mexico Brazil Argentina Chile European areas like England UK Switzerland France Poland Italy Netherlands Sweden Spain Australia Korea etc.